%{tishi_zhanwei}%

H99-1 Epoxy Antistatic and Oil-resistant Paint with Corrosive Prevention

H99-1 Epoxy Antistatic and Oil-resistant Paint with Corrosive Prevention

Intended Uses Suited for interior surface of tank loading crude oil gasoline, kerosene, gas oil and as anticorrosive and antistatic coating. Also be used in the site required resistance to static. It forms a coating with excellent adhesion, flexibility, impact resistance, good oil and corrosive resistance as well as good antistatic property.
Product Description Light gray, Using metallic oxide modified micapowder as conductive medium.
Product Information Volume Solids 75%
Dry Film Thickness 100 microns equivalent to 133 microns of wet film
Theoretical Coverage 187g/m2
Pratical Coverage Allow appropriate loss
Application Details Mix Ratio A(Paint media):B(Curing agent)=20:3(By weight)
Method of Application  
Airless Spray Recommended-Tip range: 0.53-0.68mm; Total output fluid pressure: >17MPa(>17kg/c㎡)
Brush or Roller Recommended
Conventional Spray Not Recommended
Thinner Maximum thinning: less than<5% X-7
Cleaner X-7
Pot Life 4-6 hours at 25℃
Storage Life One year
Drying Time Substrate Temperature Touch Dry(h) Hard Dry(h) Overcoating Interval
Minimum Maximum
25℃ 2 24 24 hours
Above 10℃
5 days
Above 10℃
Storage and Handing Storage Store in cool and dry conditions
Pack Size A: 20 kg in 20 liter container
B: 3 kg in 4 liter container
Flash Point 22℃
Specific Gravity Approx 1.40kg/L
Specification and Surface Preparation Remove rust to Sa2.5 and then integrall coating is conducted.
Limitations Recommended coat: Spray two coats with high-pressure airless spray, for the sake of 200 microns of dry film thickness.
Proceding coat: Inorganic silicate primer etc.
Safety Precautions This product should be used in painting area by professional operations. When painting, please refer to Product Data Sheet and MSDS. Consult our company if consumers could not completely understand the precautions for safety and health when applying this product.
This product is a kind of solvent-based paint. In order to avoid danger or accident, minimal safety precautions, as follow, should be done;
The paint contains volatile solvent and is flammable. So must keep away form sparks and open flames. No smoking at application site. Effective precautions (such as using explosion-proof electrical equipments, no static electricity accumulation or metal collision etc) also should be done so as to avoid producing sparks. Flash point of paint, mentioned above o Product Data Sheet, is the lowest temperature at which mixture of the volatile materials of paint can ignite or explode with air.
Enough ventilation is necessary at application site. In order to remove any danger of explosion, must keep the ratio of gas to air is less than 10%, the minimum explosive limit in general. Therefore, 200m3 of ventilation quantity per 1kg solvent (according to the solvent) is necessary.
Protect skin and eyes, and avoid touching with paints (Recommend to wear working clothes, gloves, eye protection, face masks, barries creams and so on). If paint gets in touch with skin, wash fully with a large amount of fresh water and soap or appropriate commercial cleaner. In case of eyes being contaminated, rinse with fresh water for 10min at least and give medical treatment immediately.
Recommend face guard with ventilation pipe for the sake of no absorption of paint fog and harmful solvent gas, especially in bad ventilation.
Handle empty containers with care and do not bring about environmental contamination.
NOTICE: If consumers have not taken effective safety precautions (Refer to the specifications), out company will NOT be responsiblefor any accident.