H53-5 Epoxy Iron Red Primer

H53-5 Epoxy Iron Red Primer

Intended Uses Excellent adhesion and anti corrosive effect, also with water and acid resistance. Suited for painting the surface of steel structure or concrete as primer.
Product Description High-performance. Two packages, Iron red.
Product Information Volume Solids 55%
Dry Film Thickness 40 microns
Theoretical Coverage 102g/m2
Pratical Coverage Allow appropriate loss
Application Details Mix Ratio A:B=100:15(By weight)
Method of Application  
Airless Spray Recommended
Brush or Roller Recommended
Conventional Spray Adoptable
Thinner X-7
Cleaner X-7
Pot Life 5℃-12h 25℃-8h 35℃-3h
Storage Life One year
Drying
Time
Substrate
Temperature
Touch
Dry
(h)
Hard
Dry
(h)
Overcoating Interval
Minimum Maximum
5℃ 2 24 12 hours 14 days
Storage and Handing Storage Store in cool and dry conditions
Pack Size Component A: 20kg, Component B: 3kg.
Flash Point Above 38℃
Specific Gravity Approx 1.4kg/L
Specification and Surface Preparation The steel surface: Blast clean to Swedish Standard SIS055900 Sa2.5 or rust-removed manually or with power tool to St3.
Limitations This product can not fully cure below 5℃, so the substrate temperature should be maintained above 10℃ for good effect.
Safety Precautions This product should be used in painting area by professional operations. When painting, please refer to Product Data Sheet and MSDS. Consult our company if consumers could not completely understand the precautions for safety and health when applying this product.
This product is a kind of solvent-based paint. In order to avoid danger or accident, minimal safety precautions, as follow, should be done;
The paint contains volatile solvent and is flammable. So must keep away form sparks and open flames. No smoking at application site. Effective precautions (such as using explosion-proof electrical equipments, no static electricity accumulation or metal collision etc) also should be done so as to avoid producing sparks. Flash point of paint, mentioned above o Product Data Sheet, is the lowest temperature at which mixture of the volatile materials of paint can ignite or explode with air.
Enough ventilation is necessary at application site. In order to remove any danger of explosion, must keep the ratio of gas to air is less than 10%, the minimum explosive limit in general. Therefore, 200m3 of ventilation quantity per 1kg solvent (according to the solvent) is necessary.
Protect skin and eyes, and avoid touching with paints (Recommend to wear working clothes, gloves, eye protection, face masks, barries creams and so on). If paint gets in touch with skin, wash fully with a large amount of fresh water and soap or appropriate commercial cleaner. In case of eyes being contaminated, rinse with fresh water for 10min at least and give medical treatment immediately.
Recommend face guard with ventilation pipe for the sake of no absorption of paint fog and harmful solvent gas, especially in bad ventilation.
Handle empty containers with care and do not bring about environmental contamination.
NOTICE: If consumers have not taken effective safety precautions (Refer to the specifications), out company will NOT be responsiblefor any accident.