HL52-4 High-build Coal-tar Epoxy Paint For Winter
HL52-4 High-build Coal-tar Epoxy Paint For Winter (primer/finish, two components)
| Intended Uses | Provide long life protection of steel in severely corrosive condition such as soaking position including ship bottom, crude oil tank, fuel tank and ballast tank etc. Application temperature may be low to 20℃ as low temperature curing epoxy paint. Two components. It from a tough coating with excellent resistance to abrasion, sea water, crude oil, flue oil etc. | |||||||||||||
| Product Description | Primer: brown; finish: black. Two packages, component B is universal curing agent for primer of finish. | |||||||||||||
| Product Information | Volume Solids | 62.5% | ||||||||||||
| Dry Film Thickness | 125 mircons equivalent to 200 mircons of wet film. | |||||||||||||
| Theoretical Coverage |
Primer:278g/m2 Finish:260g/m2 |
|||||||||||||
| Practical Coverage | Allow appropriate loss | |||||||||||||
| Application Details | Mix Ratio | Component A (paint mdeia): Component B (curing agent)=100:8(By weight) | ||||||||||||
| Method of Application | ||||||||||||||
| Airless Spray | Recommended-Tip range 0.53-0.65mm, Total output fluid pressure: 19.7MPa(197Kg/sq.cm) | |||||||||||||
| Brush or Roller | Recommended | |||||||||||||
| Conventional Spray | Not recommended | |||||||||||||
| Thinner | Maximum thinning: <5% | |||||||||||||
| Cleaner | X-7 | |||||||||||||
| Pot Life | 10℃2 hours | |||||||||||||
| Storage Life | One year | |||||||||||||
|
||||||||||||||
| Storage and Handing | Storage | Store in cool and dry conditions | ||||||||||||
| Pack Size |
A: 25kg in 20 liter container B: 2kg in 4 liter container |
|||||||||||||
| Flash Point | 25℃ | |||||||||||||
| Specific Gravity | Primer: 1.4kg/L, Finish: 1.3kg/L. | |||||||||||||
| Specification and Surface Preparation | New Steel: Blast to Swedish Standard Sa2.5. If need temporary protection, use proper shop primer and remove the damaged shop primer and dirt prior to application. | |||||||||||||
| Limitations |
Recommended coat: Spray one coat of primer and one coat of finish, with high-pressure airless spray for the purpose of 250 microns of dry film thickness. Preceding coat: Epoxy zinc rich shop primer, epoxy zinc dust shop primer, epoxy iron red shop primer, inorganic zinc silicate shop primer. Also Painted be directly on surface treated to Sa2.5. |
|||||||||||||
| Safety Precautions |
This product should be used in painting area by professional operations. When painting, please refer to Product Data Sheet and MSDS. Consult our company if consumers could not completely understand the precautions for safety and health when applying this product. This product is a kind of solvent-based paint. In order to avoid danger or accident, minimal safety precautions, as follow, should be done; The paint contains volatile solvent and is flammable. So must keep away form sparks and open flames. No smoking at application site. Effective precautions (such as using explosion-proof electrical equipments, no static electricity accumulation or metal collision etc) also should be done so as to avoid producing sparks. Flash point of paint, mentioned above o Product Data Sheet, is the lowest temperature at which mixture of the volatile materials of paint can ignite or explode with air. Enough ventilation is necessary at application site. In order to remove any danger of explosion, must keep the ratio of gas to air is less than 10%, the minimum explosive limit in general. Therefore, 200m3 of ventilation quantity per 1kg solvent (according to the solvent) is necessary. Protect skin and eyes, and avoid touching with paints (Recommend to wear working clothes, gloves, eye protection, face masks, barries creams and so on). If paint gets in touch with skin, wash fully with a large amount of fresh water and soap or appropriate commercial cleaner. In case of eyes being contaminated, rinse with fresh water for 10min at least and give medical treatment immediately. Recommend face guard with ventilation pipe for the sake of no absorption of paint fog and harmful solvent gas, especially in bad ventilation. Handle empty containers with care and do not bring about environmental contamination. NOTICE: If consumers have not taken effective safety precautions (Refer to the specifications), out company will NOT be responsiblefor any accident. |
|||||||||||||
Category: